Melt flow indexer TATEYAMA KAGAKU L220
VNĐ
Melt flow indexer TATEYAMA KAGAKU L220
VNĐ
Make use of the product with a sense of security as it is a test instrument of a sensor manufacturer.
Exremely reliable with an excellent track record in this field:
- Remperrature indication resolution 0.01 degrees C
- Temperature variation Within ±0.2 degrees C
The comparison of a conventional model on the size:
- Achieved a downsizing of around 20%
The comparison of a conventional meodel on the peak power consumption:
- Achieced 25% cut back
Melt flow indexer (standard type) ...
VNĐ
Melt flow indexer (standard type) ...
VNĐ
This is a extruding type plastimeter which is made for testing the flo of thermal plastic resin. It is made to meet JIS K7210, ASTM 01238 and ISO 1133.
Multipoint temperature data loggers ...
VNĐ
Multipoint temperature data loggers ...
VNĐ
LT-200 series is a multipoint temperature data logger capable of measuring, recording and monitoring via PC outputting.
Temperature resolution:0.001 ℃
Accuracy :±0.02 ℃
Sampling period: 0.2 s
High precise temperature logger TATEYAMA ...
VNĐ
High precise temperature logger TATEYAMA ...
VNĐ
High precise
Resolutlon :0.01°C
Preclslon (Stability): ±0.1°C
JCSS Calibration Service Available
NEW
GPS Aquameter: Handheld device with ...
VNĐ
GPS Aquameter: Handheld device with ...
VNĐ
The GPS Aquameter is the original handheld water quality meter with built in GPS. The built in GPS receiver allows the meter to record the location of every dataset, meaning you will always know where your data was captured. The meter is designed to be picked up and used by anyone intuitively. It requires no boot up or warm up time and allows you to record data with a single button press.
NEW
AP-2000 / AP-2000-D: Advanced portable ...
VNĐ
AP-2000 / AP-2000-D: Advanced portable ...
VNĐ
The AP-2000 is the smaller of our advanced portable multiparameter water monitoring probes. It comes with a range of standard sensors included, it also offers some customisation options that allow you to add even more sensors to the probe. All of our probes are constructed from tough marine grade aluminium that has been hard anodised, making it suitable for use in both fresh and salt waters.
NEW
LeveLine-EWS - Early flood warning ...
VNĐ
LeveLine-EWS - Early flood warning ...
VNĐ
Flooding is a continuous threat for many people in the UK. The LeveLine-EWS functions as both an early flood warning system, providing instant alerts to rising water levels and as a continuous water level monitor.
MVE Spectrum Series
VNĐ
MVE Spectrum Series
VNĐ
The Spectrum series is designed for the user who has small capacity needs, but requires long-term storage and low liquid nitrogen consumption in a convenient lightweight package. By integrating features users requested with the widest variety of holding times and storage capacities, Chart Aluminum Freezers are the units of choice.
AquaStation – Self calibrating remote ...
VNĐ
AquaStation – Self calibrating remote ...
VNĐ
The AquaStation independent monitoring station is a breakthrough in remote water quality monitoring. The AquaStation is able to independently collect data, keep its sensors clear of fouling and calibrate its sensors remotely via its built in telemetry system.
Field Emission Transmission Electron ...
VNĐ
Field Emission Transmission Electron ...
VNĐ
•Cold field emission electron source benefits nanoscale analysis with its high brightness and high energy resolution. Its inherent high coherency greatly contributes to ultrahigh resolution imaging and electron holography*.300kV accelerating voltage
•300kV accelerating voltage allows atomic resolution imaging for thick specimens. Metals and ceramics with high atomic numbers are less electron transparent and often need to be observed at 300kV accelerating voltage.Unique analytical capabilities
•Newly introduced spatially resolved EELS* and in situ SEM/TEM imaging* nanobeam electron diffraction provide sophisticated and unique analytical capabilities.Holder linkage with FIB system*
•Hitachi FIB-compatible specimen holder* requires no tweezer handling of TEM grid between FIB fabrication and TEM observation and ensures high sample throughput TEM analysis. Hitachi's unique specimen rotation holder* enables real-time multidirectional structural analysis together with STEM unit*.User-friendly operation
•Windows-based TEM/STEM* computer control, motor-driven movable aperture, and 5-axis motor stage make the high-end TEM more easily to access, 10 minutes high voltage ready and one minute specimen exchange result in high sample throughput for TEM analysis.
Transmission Electron Microscope H-9500
VNĐ
Transmission Electron Microscope H-9500
VNĐ
User-friendly operation
•Windows®* compatible GUI design
•High specimen throughput, 1 minute for specimen exchange and 5 minutes for voltage ramp up (300 kV) and beam on.
Stable high resolution microscopy
•Point-to-point resolution of 0.18nm and lattice resolution of 0.1nm
•A stable 5-axis eucentric goniometer stage
Excellent performance reliability
•Field-proven 10-stage accelerator gun design
•High voltage resistor cable design
Valuable optional accessories
•Compatible specimen holder for use with Hitachi TEM, FIB and STEM systems
•A variety of specimen holders that provide heating, cooling and gas-injection capabilities for atomic resolution dynamic studies.
Hitachi Spherical Aberration Corrected ...
VNĐ
Hitachi Spherical Aberration Corrected ...
VNĐ
Cs-corrected high-resolution imaging & high-sensitivity analysis with unmatched throughput
In the fields ranging from R&D to quality control of advanced nano materials and semiconductor devices, there have been increased demands in recent years for improving spatial resolution and analytical performance for electron microscopes. Aberration correction provides a prominent solution to these demands. Hitachi High-Technologies had previously commercialized electron microscopes equipped with spherical aberration correction capability, since then continued efforts toward pursuing the concept of providing both high throughput and high performance benefited from aberration correction. The HD-2700 STEM with the newly developed Hitachi spherical aberration corrector realized this concept successfully.
[VN] Hệ thống đặc tính hóa ...
VNĐ
Gifts:
[VN] Hệ thống đặc tính hóa ...
VNĐ
[VN] Hitachi NE4000 nano EBAC là một hệ thống đo dùng chùm tia điện tử để đặc tính hóa tính chất về điện học và EBAC phân tích và thu ảnh của thiết bị vi điện tử như liên kết, vật liệu và linh kiện.
Promotion:
Ion Sputter MC1000
VNĐ
Ion Sputter MC1000
VNĐ
- Type: Diode discharge magnetron type (electric field perpendicular to magnetic field)
- Electrode form: Opposed parallel disk (magnet embedded)
- Voltage: 0.4 kV DC max. (variable through phase control)
- Current: 40 mA DC max.
High Accuracy Coolant Circulation Unit ...
VNĐ
High Accuracy Coolant Circulation Unit ...
VNĐ
- Item: Specifications
- Usable environment: Room temperature: 5 - 30°C, RH: 70% or less
- Cooling water temperature: 20°C
- Water pressure: 95/127 kPa (lift: 9.5/12.7 m) (50/60 Hz)
- Water flow: 27/31 liters/min. (maximum)
- A flow regulator valve is built in.
Magnetic stirrer with heating IKA RET ...
VNĐ
Magnetic stirrer with heating IKA RET ...
VNĐ
WORLD’S FIRST: Safety magnetic stirrer with heating and integrated weighing function. The clear, multilingual TFT display makes it easy to set all parameters.
Integrated temperature control feature enables connection of a temperature probe which can be placed directly in the medium to control medium temperature with a high degree of precision. PT 100 temperature sensor is included with purchase of RET control. The stainless steel composite hot plate, reaching a temperature of 340 °C, enables rapid heating.
RS 232 and USB interface enables pc control of the magnetic stirrer and documentation of all test parameters. Furthermore firmware updates can be installed through the USB interface. The Lock function prevents inadvertent changes of speed and temperature settings.
As a safety feature, the current temperature is displayed when the unit is switched off but surface is still hot. Below 50 °C the display turns off automatically .
H 44 Boss head clamp
VNĐ
H 44 Boss head clamp
VNĐ
For fastening the holding rod H 38 to the support rod H 16 V.
Clamping range - stand: 10 - 11 mm
Clamping range - extension arm: 11 mm
Material: cast aluminium
H 16 V Support rod
VNĐ
H 16 V Support rod
VNĐ
Stainless steel support rod for all magnetic stirrers with M 10 threaded bushing.
H 38 Holding rod
VNĐ
H 38 Holding rod
VNĐ
For fastening ETS-D5 or ETS-D6 to the support rod H 16 V.
Sensor đo nhiệt độ IKA ETS-D5
VNĐ
Sensor đo nhiệt độ IKA ETS-D5
VNĐ
Dải đo nhiệt độ: -50 oC đến +450 oC
Độ chính xác: ±0.2 + độ sai số cảm biến PT1000 (DIN IEC 751 Class A) K
Độ chính xác gia nhiệt: 0.1 ±K
Độ chính xác điều khiển với cảm biến: 0.5 ±K
Chiều sâu nhúng cảm biến tối đa: 200 mm
Kích thước: 82 x 83 x 22 mm
Trọng lượng: 0.2 kg
Dải nhiệt độ hoạt động: 0 - 60 oC
Độ ẩm hoạt động: 80 %
Tiêu chuẩn an toàn DIN EN 60529: IP 54
Điện áp DC: 8 - 16V
M 20 Universal mill
VNĐ
M 20 Universal mill
VNĐ
Process type: batch
Operating principle: cutting/impact
Motor rating input: 450 W
Motor rating output: 225 W
Speed max: 20000 rpm
Circumferential speed max: 72 m/s
Usable volume max: 250 ml
Feed hardness max: 5 Mohs
Feed grain size max: 7 mm
IKA C 1 Calorimeter
VNĐ
IKA C 1 Calorimeter
VNĐ
The C 1 static jacket oxygen bomb calorimeter represents a giant leap forward in calorimeter technology by featuring a high degree of automation in a compact design; the smallest calorimeter footprint available.
It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.
Elmasteam 3000 high-performance steam ...
VNĐ
Elmasteam 3000 high-performance steam ...
VNĐ
Professional high-performance steam cleaning unit, operating pressure 8 bar, suitable for the use in industry, jeweller‘s workshop, dental laboratory and workshop. Available with either 3 or 5 litres filling volume; the steam can be generated from tap water or distilled water. The high heating power of the unit ensures a constant steam supply with only minimum pressure losses even during permanent operation.
Magnetic stirrer with heating IKA RET ...
VNĐ
Magnetic stirrer with heating IKA RET ...
VNĐ
WORLD’S FIRST: Safety magnetic stirrer with heating and integrated weighing function. The clear, multilingual TFT display makes it easy to set all parameters.
Integrated temperature control feature enables connection of a temperature probe which can be placed directly in the medium to control medium temperature with a high degree of precision. PT 100 temperature sensor is included with purchase of RET control. The stainless steel composite hot plate, reaching a temperature of 340 °C, enables rapid heating.